Description
MULTICARE IN
DIAGNOSTIC AID MULTIPARAMETER WITH CAPILLARY ASPIRATION
multiCare in © is a diagnostic aid multiparameter with capillary aspiration for the determination of the following paramenters: Glucose Cholesterol Triglycerides multiCare IN has been developed to execute several determination from fingerprint simply by changing strip. multiCare IN is a new system dedicated to glucose, cholesterol and triglycerides monitoring in whole blood. multiCare IN system is using two different technologies: AMPEROMETRIC with multiCare IN glucose Electrodes strips REFLECTOMETRIC with multiCare IN cholesterol and triglycerides strips
|
The self-checking of the glycaemia allows the diabetic patient to have immediate information about his/her glucose level, but it must be performed only after accurate training with a physician or with a qualified technician.
It is important to point out that the self-checking cannot be performed without constant follow up by the physician (to make up a timetable, to evaluate the results and to define a therapy).
With the multiCare-in Cholesterol strips it is possible to quickly check cholesterol levels in the blood and inform the family physician to find a suitable therapy or to check-up on an existing therapy. The level of cholesterol in the blood is influenced by the diet, but also by: medicines, diabetes mellitus, pregnancy and severe illnesses.
It is recommended to check blood cholesterol concentration on all people who are used to smoke, to drink too much alcohol and to eat fat and are over weighted or do not exercise enough.
It is specially recommended to people who already had heart disease or with familiar cases of heart diseases before the age of 60. Perform the test at fast for at least 9 hours.
Using the multiCare-in Triglycerides strips it is possible to quickly check triglycerides level in the blood.
The level of triglycerides in the blood is influenced from fat feeding or from alterations of the metabolism of lipids but also from diabetes mellitus, nephrotic syndromes, pancreas problems, acute alcoholism.
It is important to inform the family physician to find a suitable therapy or to check-up on an existing therapy.
Perform the test when you have not had anything to eat or drink (except water) for at least 12 hours.
TECHNICAL FEATURES
METER | |
---|---|
Measurement range
|
10-600 mg/dl (0.6-33.3 mmol/l) glucose ELECTRODES 130-400 mg/dl (3,3-10,2 mmol/l) cholesterol 50-500 mg/dl (0,56-5,6 mmol/l) TRIGLYCERIDES |
Power Source
|
2X3V lithium button cell, type CR 2032. The battery can be used for approx. 1 year with 3 measurements per day (approx. 1000 measurements) |
Switch On
|
Automatic Switch on/off by strip detection |
Dimension
|
Length: 97 mm Height: 20,5 mm Width: 49 mm |
Weight
|
65 g (incl. battery) |
Indicator
|
LCD display |
Climatic operating condition
|
Temperature limits: 10 to 40 °C Humidity limits: 0% to 90% relative humidity (non-condensing) Altitude limit: 3000 metres |
Memory capacity
|
500 measured values with time and date |
Interface for data processing
|
Connecting cable |
Warranty of the instrument
|
3 years |
Contents of the instrument box
|
1 meter, 1 lancing device, 1 bag of 10 sterile lancets, 1 vial of 10 glucose strips, 1 data-chip, 1 hardcase,1 user’s manual, 1 rapid guide, 1 lancing device instructions |
GLUCOSE ELECTRODES STRIPS | |
---|---|
Sample to be used
|
Fresh capillary whole blood Minimum volume: 0.5 µl |
Range of Measurement
|
10-600 mg/dl (0,6-33,3 mmol/l) |
Averange time for reading
|
5 second |
Storage conditions
|
5-30 °C |
Table of results
|
Glucose below 10 mg/dL (0,6 mmol/L) = LO* Glucose between 10 mg/dL (0,6 mmol/L) and 600 mg/dL (33,3 mmol/L) = the numerical result Glucose above 600 mg/dL (33,3 mmol/L) = HI** *Repeat the test. **Such results mean that the glucose concentration in the sample is very elevated and it indicates a serious risk. CONTACT A PHYSICIAN IMMEDIATELY. Normal Values at fasting 70-110 mg/dL (3,9-6,1 mmol/L) |
Packaging
|
Boxes of 25, 50 pcs |
CHOLESTEROL STRIPS | |
---|---|
Sample to be used
|
Fresh capillary whole blood |
Range of Measurement
|
130-400 mg/dl (3,3-10,3 mmol/l) |
Averange time for reading
|
About 30 seconds |
Storage conditions
|
5-30 °C |
Table of results
|
Cholesterol below 130 mg/dL (3.3 mmol/L) = LO* Cholesterol between 130 mg/dL (3.3 mmol/L) and 400 mg/dL (10.2 mmol/L) = the numerical result Cholesterol above 400 mg/dL (10.2 mmol/L) the display = HI** *Repeat the test. **Such results mean that the Triglycerides concentration in the sample is very elevated and it indicates a serious risk. CONTACT A PHYSICIAN IMMEDIATELY. |
Cholesterol Values
|
Less than 200 mg/dL (5.1 mmol/L) = desirable values From 200 mg/dL (5.1 mmol/L) to 239 mg/dL (6.1 mmol/L) = high risk factor More than or equal to 240 mg/dL (6.1 mmol/L) = high cholesterol |
Packaging
|
Boxes of 5, 25 pcs |
TRIGLYCERIDES STRIPS | |
---|---|
Sample to be used
|
Fresh capillary whole blood |
Range of Measurement
|
50-500 mg/dl (0,56-5,6 mmol/l) |
Averange time for reading
|
About 30 seconds |
Storage conditions
|
5-30 °C |
Table of results
|
Below 50 mg/dL (0.5 mmol/L) = LO* Between 50 mg/dL (0.5 mmol/L) and 500 mg/dL (5.6 mmol/L) = the numerical result Above 500 mg/dL (5.6 mmol/L) = HI** .*Repeat the test. **Such results mean that the Triglycerides concentration in the sample is very elevated and it indicates a serious risk. CONTACT A PHYSICIAN IMMEDIATELY. |
Triglycerides Values
|
Less than 150 mg/dl (1.7mmol/L) = Normal Borderline High= 150-199 mg/dL (1.7-2.2 mmol/L) High= 200-499 mg/dL (2.3-5.6 mmol/L) Very High= 500 mg/dL (5.6 mmol/L) or above |
Packaging
|